Description
C-Rating
1.5C discharge / 1C charge cell technology; system output is controller-limited.
The Greenrich HVB-IS001 uses 96.6Ah, 51.2V battery modules (approximately 4.95kWh each). Greenrich specifies cell technology capable of 1C charging and 1.5C discharging.
The listed HVCB3-125 controller is rated at 100A continuous and 125A maximum. For a 96.6Ah series string, these correspond to approximately 1.04C continuous and 1.29C maximum controller current. The manufacturer lists 50A standard discharge (approximately 0.52C) and 125A maximum discharge, limited by the breaker. The 1.5C cell rating should therefore not be treated as the complete system’s continuous output rating.
Adding modules in series increases voltage and stored energy while retaining the string’s 96.6Ah capacity. Actual charge/discharge current depends on the installed controller, BMS limits, temperature, state of charge and the connected inverter or PCS.
Manufacturer specifications: Greenrich HVB-IS001 system
Product Nr: HVB-IS001